Commercial Outdoor Security Lighting for Perimeters
Design risk-appropriate lighting along fences, yards and access points to deter, detect and recognize. We align with IES G-1 (security lighting principles), IES RP-8 (adjacent roadways) and EN 12464-2 (outdoor workplaces), and we size vertical/semicylindrical illuminance for faces, gates and camera corridors. Optics, mounting and spacing are optimized from photometry to deliver uniformity with low glare, while BUG/TM-15 controls spill to neighbors and skylines. Submit your site plan for a standards-based layout, calculation report and bill of materials—available in مصباح LED يعمل بالشبكة أو solar الحلول.
Key Considerations for Perimeter & Security Lighting

Standards alignment
IES G-1 for security lighting, EN 12464-2 for outdoor work areas, and IES RP-8 where roadways interface.

Vertical light for recognition
الهدف vertical/semicylindrical illuminance at gates, turnstiles, doors and camera corridors to reveal faces and apparel.

Glare & spill control
Manage BUG/TM-15 and veiling luminance; shield at perimeters, upper stories and neighboring properties.

Power & resilience
Scheduling and occupancy sensing; for solar, battery autonomy sized for worst-case nights and restart after outages.
Design Principles for Perimeter & Security Lighting

Risk-based classes
Lighting targets scale with risk and task—deterrence, detection and recognition—rather than a single fixed lux value.

Optics & geometry
Type II/III for perimeter runs; Type IV/V or forward-throw for yards. Pole height and spacing are calculation outcomes.

CCTV integration
توفير consistent vertical light, limit blooming/flare into lenses, and coordinate CCT/CRI with camera WDR/IR.

Color & comfort
3000–4000 K typical; CRI ≥80 near gates and ID checks for color-critical recognition.

Controls & operations
Staggered dimming for off-hours, motion-based step-ups, health monitoring and fault alerts.
الحلول حسب السيناريو
For off-grid sites, solar security lighting can be evaluated alongside LED perimeter lighting. The project brief should define perimeter geometry, pole locations, operating hours, camera or CCTV coordination, battery reserve, and maintenance access. Final photometrics, autonomy, and camera performance require site-specific review. If cameras are in scope, review the solar CCTV power and pole interfaces. Send the perimeter layout and operating brief, identifying who supplies the cameras, communications, lighting and commissioning work so the quotation has a clear supply boundary.
Fence Lines & Clear Zones
Continuous uniformity with low glare; forward-throw optics to avoid lighting the outside beyond the fence.
Gates, Guardhouses & Turnstiles
Elevated vertical/SC components for faces and IDs; back-light shielding to protect operators’ vision.
Yards, Loading Docks & Container Areas
Wide/forward distributions with mast poles; maintain shadow control between vehicles and stacks.
Camera Corridors & PTZ Overlaps
Even vertical illumination across camera FOV; avoid highlights behind subjects that cause silhouettes.
Parking & Perimeter Interfaces
Tie security foot-candles to parking code minima; cap spill at property lines and residential edges.
ما تحصل عليه
- EN 13201 / IES RP-8 compliant layout (luminance or illuminance/vertical/SC as applicable)
- ملفات القياس الضوئي (IES/LDT) + تقارير الحسابات
- Pole/foundation drawings + single-line diagram
- Bill of materials with options (LED vs Solar, pole heights, optics)
- O&M and warranty checklist
- Compliance crosswalk mapping local guidelines to EN 13201 / IES RP-8.
- Lead time, logistics and installation method statement (optional).
- Security-focused photometric package (horizontal + vertical/SC where required)
- CCTV coordination notes (camera placement, lens FOV, tilt and expected vertical E)
- Commissioning checklist with target set-points, dimming schedules and acceptance criteria
منتجات إنارة الشوارع بالطاقة الشمسية الموصى بها

جاكوار (INL-IT5)
مصابيح LED عالية الإنتاجية الكل في اثنين مع 5050 مصباح LED، ومصابيح LiFePO4 كبيرة، وبصريات متطورة - مصممة للطرق السريعة والطرق الرئيسية.

فالكون (INL-IT6)
إخراج متوسط، بصريات متعددة الاستخدامات، تركيب سريع - مثالية للشوارع والممرات والساحات.

بيسون (INL-IT7)
مدمجة وفعّالة وجاهزة للساحات المجتمعية والصناعية بقدرة تزيد عن 180 لومن/ثانية.

سيريوس (INL-AIO9)
جهاز AIO عالي الإخراج مع رأس قابل للضبط، وبصريات من النوع الثاني/الثالث، ومصابيح LED 5050 ومصابيح LiFePO4 - مصممة للطرق ذات الاتجاهين والطرق السريعة.

المجرة (INL-AIO6)
وحدات AIO المعيارية للمخرجات الصغيرة إلى المتوسطة؛ 5050 مصباح LED، و LiFePO4 وحركة اختيارية/إنترنت الأشياء - سهولة الصيانة للشوارع والممرات ومواقف السيارات.
منتجات إضاءة الشوارع LED الموصى بها
Review LED roadway luminaires for perimeter routes, gates and yard interfaces. Confirm the selected optic, mounting arrangement and control requirements through a site-specific lighting review.

INL-LED25 - مصباح الشارع LED
حزم بقدرة 100-200 واط وبصريات الطرق ومحركات تشغيل جاهزة للتحكم للطرق الرئيسية والتجميعية.

INL-LED24 - مصباح الشارع LED
50-200 واط مع بصريات دقيقة من النوعين الثاني/الثالث/خامس؛ خدمة بدون أدوات وخيارات SPD للبلديات.

INL-LED23 - مصباح الشارع LED
50-240 واط ذات نطاق إخراج عالٍ لمساحات أوسع؛ حوامل متعددة الأذرع/مثبتة على ذراع/مثبتة على ذراع.

INL-LED22 - مصباح الشارع LED
منصة متعددة الاستخدامات بقدرة 60-200 واط مع خيارات توزيعات الطرق والتحكم.

INL-LED13 - مصباح الشارع LED
60-200 واط مع غلاف متين مصبوب ومتين وتصنيفات IP/IK للشوارع والساحات في المناطق الحضرية.
