LED Street Light for Municipal & Commercial Roads
Our LED street-lighting portfolio covers five models engineered for collector roads, local streets and large parking lots. Specify roadway distributions (Type II/III/V), lumen packages across 50–240 W, and controls from 0–10 V/DALI to NEMA 7-pin photocells or nodes. We pair IP66/IK08 housings with robust 10/20 kV surge protection and corrosion-resistant finishes, then provide photometric layouts, mounting details, BOM and shop drawings so you can bid and build with confidence.Commercial LED Street Lights for Road and Municipal Projects
Quick answer: Commercial street lights should be selected from road geometry and required photometric performance, not from a wattage label alone. For grid-connected roads, commercial LED street lights combine roadway optics, surge protection and controls-ready drivers to meet the project target. Where trenching or grid access is impractical, evaluate a separate solar street-lighting system around the site’s solar resource, nightly load and autonomy requirement. Confirm every requirement against the quoted model and project documents.
What a Commercial Street-Light Quotation Should Include
- Site geometry: road class, carriageway width, lane count, pole positions, mounting height, outreach and setback.
- Lighting target: maintained illuminance or luminance, uniformity, glare limit, CCT and the required dimming or control schedule.
- Electrical and mechanical conditions: supply voltage, surge protection, IP/IK requirement, ambient temperature, corrosion exposure, wind conditions and control interface.
- Submittals: model-specific IES/LDT files, photometric layout, test and certificate scope, warranty, spare-parts plan, lead time and supply responsibilities.
The U.S. Department of Energy’s model specification for LED roadway luminaires is designed to help cities, utilities and public agencies assemble bid documents around defined product requirements rather than a wattage label alone. Inlux configurations shown on this page cover 50–240 W packages, Type II/III/V optics, controls-ready options, IP66/IK08 protection and 10/20 kV surge options; availability and compliance must be confirmed for the quoted model.
For procurement routing, compare the available street lights for sale and wholesale options, build the technical schedule with the RFQ & BOQ kit, or send the road geometry and performance target to the Inlux Solar engineering team.
Explore LED Street Light Models
Compare mounting arrangements, service access and project documentation.

INL-LED25 — LED Street Light
100–200 W packages, roadway optics and controls-ready drivers for main and collector roads.

INL-LED24 — LED Street Light
50–200 W with precise Type II/III/V optics; tool-less service and SPD options for municipalities.

INL-LED23 — LED Street Light
50–240 W high-output range for wider spacings; multiple arm/slip-fitter mounts.

INL-LED22 — LED Street Light
60–200 W versatile platform with roadway distributions and controls options.

INL-LED13 — LED Street Light
60–200 W with durable die-cast housing and IP/IK ratings for urban streets and lots.
Selection Guide
Compare the Listed Power Steps Across Five Models
A model range does not tell you every power step within it. Use this map to check the published options before requesting an exact configuration; do not assume that every series includes the same intermediate wattages.
| Model | 50 W | 60 W | 80 W | 100 W | 120 W | 150 W | 180 W | 200 W | 240 W |
|---|---|---|---|---|---|---|---|---|---|
| INL-LED25 | — | — | — | ✓ | — | ✓ | — | ✓ | — |
| INL-LED24 | ✓ | — | — | ✓ | — | ✓ | — | ✓ | — |
| INL-LED23 | ✓ | — | ✓ | — | ✓ | — | ✓ | — | ✓ |
| INL-LED22 | — | ✓ | — | ✓ | — | ✓ | — | ✓ | — |
| INL-LED13 | — | ✓ | — | ✓ | — | ✓ | — | ✓ | — |
This is a product-page selection reference, not a dated supply specification. The linked model pages contain the source tables. Confirm the model, electrical input, LED/driver combination and output package together on the quotation.
Then compare the model-specific photometric file and layout against the road’s lighting target. Enclosure, surge and control options must be confirmed for that configuration; a common portfolio description is not a series-wide qualification. These are complete AC roadway luminaires, not retrofit replacement bulbs.
Specify the LED Street Light Control Package
The published five-model portfolio covers 50–240 W packages, Type II/III/V optics, IP66/IK08 housings and 10/20 kV surge options, with photometric layouts, BOM and shop drawings available for project review. These are portfolio descriptions, not confirmation that every variant includes each feature. Match the control package to the quoted luminaire rather than treating “controls-ready” as a complete system.
| Item on the specification | What must match | What the label does not prove |
|---|---|---|
| 0–10 V dimming | The selected driver, control device and electrical design. Confirm the supported dimming range and switching behavior. | A dimming input alone does not provide remote monitoring, fault reports or a communications network. |
| DALI and any required D4i features | The named driver and control components, their supported functions and power arrangements. Verify exact product listings where certification is required. | A DALI reference is not automatic confirmation of D4i certification or every diagnostic feature. |
| NEMA 7-pin socket | The receptacle, node, electrical contact assignment and driver interface for the selected assembly. Have qualified personnel review the combination. | A physically fitting socket or node does not establish all electrical and control compatibility. |
| Networked operation | The node, communications coverage, any gateway/backhaul, platform access and ongoing service responsibilities. | The luminaire price does not necessarily include nodes, subscriptions, connectivity or commissioning. |
Approve one working combination
Before a rollout, agree a demonstration using the quoted luminaire, driver and controls. Check switching, the scheduled dimming scenes, the specified data and the agreed behavior after communications loss or power restoration. Retain the configuration and handover record; changing a driver or node later can change the approved combination.
The DALI Alliance D4i overview separates data and power requirements from connector systems. Use its product database to check a claimed certified component, not to assume certification for an entire Inlux series. Confirm the available options for the exact quotation.
How Inlux Solar’s LED Street Light Help You Win Bids and Secure Projects
With 1,000+ projects delivered across more than 60 countries, our engineering team supports model selection, photometric layouts, tender documents and after-sales coordination from project definition through handover.

Precision-Matched Specifications

All Required Certifications

Rich Project Experience

Premiun Quality with Competitive Price

Define the Control System Scope
For a grid-powered LED street-lighting order, identify the selected driver, control interface, node and any platform services separately. Confirm communications, operating behavior and commissioning responsibilities in the quotation; a control-ready luminaire alone does not establish an operating network.

Highly Customized Support
Proven Success in Major Projects
1,000+ Projects Across 60+ Countries
Inlux Solar has completed 1,000+ projects across more than 60 countries. Project support can include model selection, photometric layouts, mounting details, technical documentation and after-sales coordination according to the agreed supply scope.
























Our LED Street Lighting Success Stories
60+ Patent Certificates & 300+ Product Certifications
Quality Assured with Trusted Certifications
Our comprehensive certifications demonstrate our commitment to excellence and compliance. This means you can trust our products to meet all required specifications and standards,reducing risk and ensuring project success.




Innovative LED Street Lighting Solutions for Diverse Applications
Inlux Solar provides commercial LED street lights and solar street-lighting systems for municipal, industrial and infrastructure projects. Select the system architecture according to grid availability, road geometry, required controls and maintenance access; confirm the quoted model and project scope before procurement.
