High Mast Pole Specification Guide (Tender-Ready)

Where This Guide Fits

What to Specify (Minimum)

  • Pole height and mounting arrangement
  • Wind/EPA assumptions (or require supplier to state assumptions explicitly)
  • Corrosion environment and protection system requirement
  • Base plate and anchor bolt interface deliverables
  • Lowering device requirement (yes/no) + O&M deliverables

Deliverables to Request

  • Structural calculations + compliance statement
  • Drawings: pole sections, base plate, anchor bolts, lowering device
  • Foundation checklist + required site inputs
  • Inspection records: weld/dimensions/coating

Next Steps